- Crate for K-system
- Replacing the E-System subrack
- Max 33 insulator slots
- Short design (installation depth 211 mm)
- Connection via distribution panels
- Partial and combined assembly is possible
- Complete electrical wiring according to customer requirements
- Allows you to preserve cable routing in the distribution cabinet
- No structural changes to the distribution cabinet are required.
Spark protection barriers (K series)
- Crate for K-system
- Replacing the E-System subrack
- Max 33 insulator slots
- Short design (installation depth 211 mm)
- Connection via terminal blocks
- Partial and combined assembly is possible
- Complete electrical wiring according to customer requirements
- Allows you to preserve cable routing in the distribution cabinet
- No structural changes to the distribution cabinet are required.
- Crate for K-system
- Replacing the E-System subrack
- Max 33 insulator slots
- Long design (installation depth 300 mm)
- Connection via distribution panels
- With a middle sheet and cable channel
- Partial and combined assembly is possible
- Complete electrical wiring according to customer requirements
- Allows you to preserve cable routing in the distribution cabinet
- No structural changes to the distribution cabinet are required.
- Crate for K-system
- Replacing the E-System subrack
- Max 33 insulator slots
- Long design (installation depth 300 mm)
- Connection via distribution panels
- Partial and combined assembly is possible
- Complete electrical wiring according to customer requirements
- Allows you to keep the cable routing in the distribution cabinet
- No structural changes to the distribution cabinet are required.
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Load cell input (full or half bridge)
- Output 0 mA ... ± 20 mA or 0 V ... ± 10 V
- 2 relay contact outputs
- Programmable high/low alarm
- Configurable using PACTware or keyboard
- RS-485 interface
- Low response time
- Line Fault Detection (LFD)
- 1-channel
- 24VDC power supply (power bus)
- Potentiometer input
- Output voltage 0 V ... 10 V
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel
- 24VDC power supply (power bus)
- Potentiometer input
- Current output 0 mA ... 24 mA
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Potentiometer input
- Current output 0 mA ... 20 mA
- Lead resistance compensation adjustment
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Can be used as a signal splitter (1 input and 2 outputs)
- Voltage output 0/1 V ... 5 V
- PACTware is configured
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Potentiometer input
- Output voltage 0 V ... 5 V
- Lead resistance compensation adjustment
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Load cell input (full or half bridge)
- Output 0 mA ... ± 20 mA or 0 V ... ± 10 V
- 2 relay contact outputs
- Programmable high/low alarm
- Configurable using PACTware or keyboard
- RS-485 interface
- Line Fault Detection (LFD)
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current or voltage input
- Output: 4 ... 20 mA
- Ranges selectable by potentiometer or DIP switch
- Line Fault Detection (LFD)
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Voltage output 0/1 V ... 5 V
- PACTware is configured
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Thermocouple input
- Output 4 mA ... 20 mA
- Internal cold junction compensation
- Detecting a sensor failure
- Selectable DIP switch ranges
- 1-channel isolated barrier
- Universal use with various power sources
- Thermocouple, RTD, potentiometer, or voltage input
- Backup input TP
- Current output 0/4 mA ... 20 mA
- 2 relay contact outputs
- Configurable using PACTware or keyboard
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511