Technical specifications of the KCD2-RR2-Ex1
| Main Features | ||
|---|---|---|
| Signal type | Analog input | |
|
Parameters related to functional safety |
||
| Safety Integrity Level (SIL) | SIL 2 | |
| Systematic ability (SC) | SC 3 | |
|
Supply |
||
| Connection | Power bus or terminals 9+, 10- | |
| Nominal voltage | 19 ... 30 V DC current | |
| pulsation | within delivery tolerances | |
| Rated current | < 28 mA | |
| Power consumption | 0.35 W (24 V and 1 mA measurement current), 0.85 W (30 V and 10 mA measurement current) | |
|
Entrance |
||
| Connection side | side of the field | |
| Connection | terminals 1, 2, 3, 4 | |
| Line fault detection | Yes, on Pt100 | |
| Lead resistance | ≤ 10% of the resistance value | |
| Transmission range | 0 ... 10 mA | |
| Available voltage | 7 B | |
| Line fault detection | < 30 nA | |
|
Exit |
||
| Connection side | control side | |
| Connection | terminals 5-, 7-, 6+, 8+ | |
| Current | 0 ... 10 mA | |
| Available voltage | 0...4.2 V | |
| Malfunction signal | field voltage < 150 mV or > 4 V, depending on the disconnected lead | |
| Reverse polarity protection | for I < 10 mA or U < 20 V | |
|
Transmission characteristics |
||
| Accuracy | 0.1% | |
| Deviation |
I m ≥ 1 mA: ±0.1% of R m or ±0.1 Ω (whichever is greater) I m < 1 mA: accuracy decreases proportionally to I m . eg I m = 0.1 mA: ±1% of R m or 1 Ω (whichever is greater). |
|
|
|
The influence of ambient temperature |
I m ≥ 1 mA, R m ≥ 100 Ohm: 0.01%/K in the range of -20 ... +70 °C (-4 ... 158 °F) I m < 1 mA or R m < 100 Ohm: thermal stability decreases proportionally to I m or R m |
| Settlement time | ≤ 5 ms | |
| Rise time/fall time | ≤ 2 ms (10 ... 90%) | |
|
Galvanic isolation |
||
| Output/Power | functional insulation, rated insulation voltage 50 V AC | |
|
Indicators/settings |
||
| Display elements | LED | |
| Controls | DIP switch | |
| Configuration | via DIP switches | |
| Marking | marking space at the front | |
|
Compliance with the directive |
||
| Electromagnetic compatibility |
|
|
|
|
Directive 2014/30/EU | EN 61326-1:2013 (industrial premises) |
|
Correspondence |
||
| Electromagnetic compatibility |
NE 21:2017 EN IEC 61326-3-2:2018 |
|
| Degree of protection | IEC 60529:2001 | |
| Protection against electric shock | UL 61010-1:2012 | |
|
Environmental conditions |
||
| Ambient temperature | -40 ... 70 °C (-40 ... 158 °F) | |
|
Mechanical characteristics |
||
| Degree of protection | IP20 | |
| Connection | screw terminals | |
| weight | approx. 100 g | |
| Dimensions | 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 in) (W x H x D), case type A2 | |
| Installation | on a 35 mm DIN rail in accordance with EN 60715:2001 | |
|
Data for use in hazardous areas |
||
| EU Type Examination Certificate | BASEEFA 10 ATEX 0061X | |
|
|
Marking |
II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
|
|
|
Entrance | [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
|
|
Voltage | 9.5 V |
|
|
Current | 39.22 mA |
|
|
Power | 93 MW |
| Supply |
|
|
|
|
Maximum safe voltage | 250 V (Caution! Nominal voltage may be lower.) |
| Exit |
|
|
|
|
Maximum safe voltage | 250 V (Caution! Nominal voltage may be lower.) |
| Certificate | BASEEFA 10 ATEX 0062X | |
|
|
Marking |
II 3G Ex ec IIC T4 Gc
|
| Galvanic isolation |
|
|
|
|
Input, output | safe electrical insulation in accordance with IEC/EN 60079-11:2007, peak voltage value 375 V |
|
|
Input/Power | safe electrical insulation in accordance with IEC/EN 60079-11:2007, peak voltage value 375 V |
| Compliance with the directive |
|
|
|
|
Directive 2014/34/EU | EN IEC 60079-0:2018, EN 60079-7:2015+A1:2018, EN 60079-11:2012 |
|
International certificates |
||
| FM approval |
|
|
|
|
FM certificate | FM 19 CA 0039 X, FM 19 US 0067 X |
|
|
Control drawing | 116-0457 (cFMus) |
| UL approval | E106378 | |
|
|
Control drawing | 116-0332 (cULus) |
| IECEx certification |
|
|
|
|
IECEx Certificate |
IECEx BAS 10.0024X IECEx BAS 10.0025X |
|
|
IECEx marking |
[Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I Ex ec IIC T4 Gc |
II (1)G [Ex ia Ga] IIC