Description
Certificates and Conformities
Greenhouse Gas Models 791
- Marking according to 94/9/EC: Ex II 2 G Ex dem ia II, IIC T6; Ex II 2 D Ex tD A21 IP66 T80°C
-
EC type examination certificate: PTB 00 ATEX 3108
-
IECEx Certificate of Conformity: IECEx BKI 07.0034
-
Marking according to IECEx: Ex e II T6 / Ex ia IIC T6; Ex tD A21 IP66 T58°C
-
Permissible ambient temperature: from -20°C to +40°C (standard); from -55°C to +40°C (optional)
-
Protection class: I
-
Degree of protection according to EN 60529: IP66
Greenhouse Gas Models 731
- Marking according to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
-
EC Type Examination Certificate: BVS 13 ATEX E 037X
-
IECEx Certificate of Conformity: IECEx BVS 13.0045X
-
Marking in accordance with IECEx: Ex e IIC T6/T5 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
-
Permissible ambient temperature: from -20°C to +40°C (standard); from -55°C to +55°C (optional)
-
Protection class: I
-
Degree of protection according to EN 60529: IP66
Greenhouse Gas Models 721
- Marking according to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
-
EC Type Examination Certificate: BVS 13 ATEX 013X
-
IECEx Certificate of Conformity: IECEx BVS 13.0031X
-
Marking in accordance with IECEx: Ex e IIC T4/T5 Gb; Ex tb IIIC T80°C/T95°C/Db IP6X
-
Permissible ambient temperature: from -20°C to +40°C (standard); from -55°C to +55°C (optional)
-
Protection class: I
-
Degree of protection according to EN 60529: IP66
Greenhouse Gas Models 744
- Marking acc. according to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
-
EC Type Examination Certificate: BVS 12 ATEX E 118X
-
IECEx Certificate of Conformity: IECEx BVS 12.0071X
-
Marking in accordance with IECEx: Ex e IIC T4/T5/T6 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
-
Permissible ambient temperature: from -20°C to +40°C (standard); from -55°C to +55°C (optional)
-
Protection class: I
-
Degree of protection according to EN 60529: IP66
Greenhouse Gas Models 746
- Marking acc. according to 94/9/EC: Ex II 2 G Ex e IIC T4/T5/T6 Gb / Ex e ib [ia/ib] IIC T4/T5/T6 Gb; Ex II 2 D Ex tb IIIC T80°C/T95°C Db IP6X
-
EC Type Examination Certificate: BVS 12 ATEX E 118X
-
IECEx Certificate of Conformity: IECEx BVS 12.0071X
-
Marking in accordance with IECEx: Ex e IIC T4/T5/T6 Gb; Ex tb IIIC T80°C/T95°C Db IP6X
-
Permissible ambient temperature: from -20°C to +40°C (standard); from -55°C to +55°C (optional)
-
Protection class: I
-
Degree of protection according to EN 60529: IP66
Design Features
Terminal boxes
- International certificates
-
Significant cost savings with the CEAG installation system
-
IP66 safety standard
-
Freely accessible connection terminals
-
Flange snapping technique
-
Retractable terminal strips
-
Internal EMC coating on request
Distribution boxes
- International certificates
-
Significant cost reduction thanks to the CEAG fastening system
-
Freely accessible connection terminals
-
IP66 safety standard
-
Version for metal entrances available
Standard materials
- Body – black polyamide (models GHG 791); black glass-fibre-reinforced polyester (models GHG 721, GHG 731, GHG 744 and GHG 746)
Additionally
All products on the website are original and imported into the Republic of Kazakhstan in compliance with all laws and regulations, and only with the appropriate certificates.