- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input -10 V ... 10 V
- Transmission frequency up to 50 kHz
- Output voltage -10 V ... 10 V
Peripherals and components
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 V ... 9 V
- Output voltage 0 V ... 9 V
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1%
- Line Fault Detection (LFD) for Pt100
- Case width 12.5 mm
- Connection via spring terminals with push-in technology
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 V ... -20 V
- Vibration sensor inputs
- Field voltage/current source
- Output voltage 0 V ... -20 V
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 mV ... ± 50 mV
- Output voltage 0 mV ... ± 50 mV
- Selectable up/down scale sensor failure detection
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input -10 V ... 10 V
- Output voltage -10 V ... 10 V
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 V ... 12 V
- Output voltage 0 V ... 12 V
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current input/output 4 mA ... 20 mA
- HART-IP or transmitter power supply
- Low voltage drop
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- Current input/output 4 mA ... 20 mA
- Accuracy 0.1%
- Object parameter I o /I sc = 0 mA
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current input/output 0 mA ... 40 mA
- I/P or power supply of the converter
- Accuracy 1%
- Reverse polarity protection
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1%
- Line Fault Detection (LFD) for Pt100
- Case width 12.5 mm
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Current and voltage input
- Current or voltage output
- Factory preset input/output
- Accuracy 0.1%
- Up to SIL 2 in accordance with IEC/EN 61508