- 2-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Can be used as a signal splitter (1 input and 2 outputs)
- Current output 0/4 mA ... 20 mA
- Receiver or source mode
- PACTware is configured
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
Spark protection barriers (K series)
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Current output 0/4 mA ... 20 mA
- Receiver or source mode
- PACTware is configured
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Potentiometer input
- Current output 4 mA ... 20 mA
- Lead resistance compensation adjustment
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Potentiometer input
- Output voltage 0 V ... 10 V
- Lead resistance compensation adjustment
- Accuracy 0.05%
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Backup input TP
- Current output 0/4 mA ... 20 mA
- 2 relay contact outputs
- Configurable using PACTware or keyboard
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- 2- or 3-wire Pt100 RTD input
- Output 4 mA ... 20 mA, selectable temperature linearization
- Selectable DIP switch ranges
- Detecting a sensor failure
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Thermocouple, RTD, potentiometer, or voltage input
- Current output 0/4 mA ... 20 mA
- Receiver or source mode
- PACTware is configured
- Line Fault (LFD) and Sensor Burnout Detection
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current input/output 4 mA ... 20 mA
- Accuracy 0.1%
- Object parameter I o /I sc = 0 mA
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1%
- Line Fault Detection (LFD) for Pt100
- Case width 12.5 mm
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 mV ... ± 500 mV
- Output voltage 0 mV ... ± 500 mV
- Selectable up/down scale sensor failure detection
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input -10 V ... 10 V
- Transmission frequency up to 50 kHz
- Output voltage -10 V ... 10 V
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Voltage input 0 V ... 9 V
- Output voltage 0 V ... 9 V
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Resistance and RTD input (Pt100, Pt500, Pt1000)
- Resistance output
- Accuracy 0.1%
- Line Fault Detection (LFD) for Pt100
- Case width 12.5 mm
- Connection via spring terminals with push-in technology
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- SMART fire alarm input
- Current input 1 mA ... 20 mA