- 1-channel signal generator
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA...20 mA or 0/1 V...5 V
- Terminal blocks with test sockets
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
K-system
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 20 VDC ... 30 VDC, non-polarized
- Safety relay contact output
- Test impulse immunity
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 16 VDC ... 30 VDC, non-polarized
- Safety relay contact output
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 19 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 8 VDC ... 60 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 19 VDC ... 26.4 VDC
- Recommended connection voltage: 8 VDC ... 60 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from de-energized to safe function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849
- 1-channel signal generator
- 24V DC power supply
- Discrete input 19 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from de-energized to safe function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 8 VDC ... 60 VDC
- Relay contact output for transition from de-energized to safe function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849
- 1-channel signal generator
- 24V DC power supply
- Discrete input 19 VDC ... 26.4 VDC
- Recommended connection voltage: 8 VDC ... 60 VDC
- Relay contact output for transition from de-energized to safe function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 19 VDC ... 26.5 VDC, non-polarized
- Relay contact output for transition from voltage to safety function
- Test impulse immunity
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 19 VDC ... 26.5 VDC, non-polarized
- Relay contact output for transition from voltage to safety function
- Test impulse immunity
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 19 VDC ... 26.5 VDC, non-polarized
- Relay contact output for transition from de-energized to safe function
- Test impulse immunity
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 19 VDC ... 26.5 VDC, non-polarized
- Relay contact output for safe mode de-energization function
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- Up to PL e in accordance with EN/ISO 13849