- 2-channel signal generator
- Universal use with various power sources
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 1 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Configurable using PACTware or keyboard
- Line Fault Detection (LFD)
Peripherals and components
- 1-channel signal generator
- Universal use with various power sources
- Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts
- Input frequency 1 MHz ... 10 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel signal generator
- Universal use with various power sources
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 12 kHz
- 2 relay contact outputs
- Overriding the launch
- Configurable via keyboard
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- Speed control up to 40 kHz
- 1 pre-selected value with relay output and LED indicator
- Possibility of connecting 2-, 3-, 4-wire sensors and NAMUR sensors, as well as a rotary encoder
- Launch delay
- Menu control via 4 buttons on the front panel
- Measuring the period
- The output signal can be inverted
- Display units can be set between 0.1...2.5 sec.
- 2-channel signal generator
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 1 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Configurable using PACTware or keyboard
- Line Fault Detection (LFD)
- 1-channel signal generator
- 24VDC power supply (power bus)
- Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts
- Input frequency 1 MHz ... 10 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 2-channel signal generator
- Power supply 24V DC
- PNP/push-pull, dry contacts or NAMUR inputs
- Selectable trip frequency values
- 2 relay contact outputs
- Overriding the launch
- Selectable operating mode
- Without line fault detection
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 12 kHz
- 2 relay contact outputs
- Overriding the launch
- Configurable via keyboard
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel signal generator
- 24VDC power supply (power bus)
- Level sensor input
- Setting range 1 kOhm ... 30 kOhm
- Relay contact output
- Minimum/maximum control
- 2-channel signal generator
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Can be used as a signal splitter (1 input and 2 outputs)
- 2 x 2 relay contact outputs with AND logic
- Line Fault Detection (LFD)
- Reversible operation mode
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 2-channel signal generator
- 24VDC power supply (power bus)
- Level sensor input
- Setting range 1 kOhm ... 150 kOhm
- Relay contact output
- Adjustable time delay up to 10 sec
- Minimum/maximum control
- Line Fault Detection (LFD)
- 2-channel signal generator
- Power supply 230 V AC
- Level sensor input
- Setting range 1 kOhm ... 150 kOhm
- Relay contact output
- Adjustable time delay up to 10 sec
- Minimum/maximum control
- Line Fault Detection (LFD)
- 1-channel signal generator
- Power supply 230 V AC
- Level sensor input
- Setting range 1 kOhm ... 30 kOhm
- Relay contact output
- Minimum/maximum control
- 1-channel signal generator
- Power supply 115 VAC
- Level sensor input
- Setting range 1 kOhm ... 150 kOhm
- Relay contact output
- Fault relay contact output
- Adjustable time delay up to 10 sec
- Minimum/maximum control
- Line Fault Detection (LFD)
- 2-channel signal generator
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- 2 active transistor outputs
- Reversible operation mode
- Line Fault Detection (LFD)
- Case width 12.5 mm
- Connection via spring terminals with push-in technology
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508