- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 45mA at 12VDC
- Case width 12.5 mm
- Up to SIL 3 in accordance with IEC/EN 61508
Spark protection barriers (K series)
- 2-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 45mA at 15VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 45mA at 12VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 45mA at 10VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Logical input
- Output 100mA at 13VDC
- Variable outputs for operating solenoids with 2 coils
- High power output for gas group IIB
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- Output 45mA at 15VDC
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- Output 45mA at 12VDC
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- Output 45mA at 10VDC
- Resistance to test impulse
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 45mA at 10VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Case width 12.5 mm
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 45mA at 12VDC
- Resistance to test impulse
- Case width 12.5 mm
- Connection via spring terminals with push-in technology
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Output 15.3VDC at 17mA
- 3 logic inputs with AND/OR logic
- Service port for functional testing of the isolator
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 80 mA at 11 VDC. current
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 100 mA at 10 VDC. current
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 45mA at 12VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Case width 12.5 mm
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (bus or loop powered)
- Output 65mA at 10VDC
- Line Fault Transparency (LFT)
- Resistance to test impulse
- Case width 12.5 mm
- Up to SIL 3 in accordance with IEC/EN 61508