- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Receiver or source mode
- Line Fault Detection (LFD)
- Case width 12.5 mm
- Up to SIL 3 in accordance with IEC/EN 61508
Spark protection barriers (K series)
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
- Terminal blocks with test sockets
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA ... 20 mA or 0/1 V ... 5 V
- Terminal blocks with test sockets
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (loop powered)
- Logic input 15 VDC ... 30 VDC, non-polarized
- Relay contact output
- Up to SIL 3 in accordance with IEC/EN 61508
- 2-channel isolated barrier
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 1 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Configurable using PACTware or keyboard
- Line Fault Detection (LFD)
- 2-channel isolated barrier
- Universal use with various power sources
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 1 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Configurable using PACTware or keyboard
- Line Fault Detection (LFD)
- 1-channel isolated barrier
- Universal use with various power sources
- Input for NAMUR sensors or dry contacts
- Input frequency 1 MHz ... 5 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Input for NAMUR sensors or dry contacts
- Input frequency 1 MHz ... 5 kHz
- Current output 0/4 mA ... 20 mA
- Relay contact and transistor output
- Overriding the launch
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 2-channel isolated barrier
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Selectable trip frequency values
- 2 relay contact outputs
- Overriding the launch
- Selectable operating mode
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (power bus)
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 5 kHz
- 2 relay contact outputs
- Overriding the launch
- Configurable via keyboard
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- Power supply 230 V AC
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 5 kHz
- 2 relay contact outputs
- Overriding the launch
- Configurable via keyboard
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- Power supply 115 VAC
- Dry contact or NAMUR inputs
- Input frequency 1 MHz ... 5 kHz
- 2 relay contact outputs
- Overriding the launch
- Configurable via keyboard
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508 / IEC/EN 61511
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 65mA at 9.8VDC
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 45 mA at 10 VDC. current
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel isolated barrier
- 24VDC power supply (loop powered)
- Current limit 45mA at 12VDC
- Case width 12.5 mm
- Connection via spring terminals with push-in technology
- Up to SIL 3 in accordance with IEC/EN 61508