- 2-channel isolated barrier
- 24VDC power supply (power bus)
- Analog input (AI), analog output (AO)
- Works as a transmitter power source or current generator.
- Case width 12.5 mm
- Connection via spring terminals with push-in technology.
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
Peripherals and components
- 1-channel signal generator
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Output for 4 mA ... 20 mA or 1 V ... 5 V
- Case width 12.5 mm
- Up to SIL 2 in accordance with IEC/EN 61508
- 2-channel signal generator
- 24VDC power supply (power bus)
- Analog input (AI), analog output (AO)
- Works as a transmitter power source or current generator.
- Case width 12.5 mm
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel signal generator
- Universal use with various power sources
- 2-wire and 3-wire input sensors, current and voltage sources
- Output current and voltage
- 1-channel signal generator
- Universal use with various power sources
- 2-wire and 3-wire input transducers and 2-wire current sources
- Output 0/4 mA ... 20 mA
- 2 relay contact outputs
- Adjustable on/off delay
- Programmable high/low alarm
- Linearization function (maximum 20 points)
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508/IEC/EN 61511
- 2-channel signal generator
- 24VDC power supply (power bus)
- SMART 2-wire and 3-wire input transmitters and SMART 2-wire current sources
- Output 4 mA ... 20 mA current consumer/current source
- Terminals with checkpoints
- Up to SIL 2 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (power bus)
- SMART 2-wire and 3-wire input transmitters and SMART 2-wire current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 4 mA ... 20 mA current sink/current source
- Terminals with checkpoints
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (power bus)
- SMART 2-wire and 3-wire input transmitters and SMART 2-wire current sources
- Output 4 mA ... 20 mA current consumer/current source
- Terminals with checkpoints
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (power bus)
- 2-wire and 3-wire input transducers and 2-wire current sources
- Output 0/4 mA ... 20 mA
- 2 relay contact outputs
- Adjustable on/off delay
- Programmable high/low alarm
- Linearization function (maximum 20 points)
- Line Fault Detection (LFD)
- Up to SIL 2 in accordance with IEC/EN 61508/IEC/EN 61511
- 1-channel signal generator
- 24VDC power supply (power bus)
- Input for 2-wire SMART transmitters and current sources
- Signal splitter (1 input and 2 outputs)
- Dual output 0/4 mA...20 mA or 0/1 V...5 V
- Terminal blocks with test sockets
- Up to SIL 2 (SC 3) in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 20 VDC ... 30 VDC, non-polarized
- Safety relay contact output
- Test impulse immunity
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24VDC power supply (loop powered)
- Logic input 16 VDC ... 30 VDC, non-polarized
- Safety relay contact output
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 19 VDC ... 26.4 VDC
- Recommended connection voltage: 50 VAC ... 230 VAC, 60 VDC ... 110 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508
- 1-channel signal generator
- 24V DC power supply
- Discrete input 20.5 VDC ... 26.4 VDC
- Recommended connection voltage: 8 VDC ... 60 VDC
- Relay contact output for transition from voltage to safety function
- Line Fault Transparency (LFT)
- Diagnostic function
- Up to SIL 3 in accordance with IEC/EN 61508